L18P050D15AHV CURRENT SENSOR (50A; 15V) Tamura Module Through Hole Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -30°C ~ 80°C (TA) 5µs Bidirectional 18mA ±1% L18PXXXD15
L08P050D15IPV CURRENT SENSOR (50A; 15V) Tamura Module, Single Pass Through Through Hole Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -40°C ~ 80°C (TA) 5µs Bidirectional 20mA ±1%
L08P050D15 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 10µs Bidirectional 12mA ±1%
F02P050S05 SENSOR CURRENT FLUX GATE 50A AC Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F02P
F23P050S05R FLUX-GATE CS VREFOUT (50A; +5V Tamura Module Through Hole DC ~ 100kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 12.5mV/A 500ns ±1.2% Bidirectional 55mA ±0.1% F23P
F03P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs Bidirectional 55mA ±0.1% F03P
L32P050S05BFS SENSOR CURRENT HALL 50A AC/DC Tamura Module, Single Pass Through Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 85°C 5µs Bidirectional 15mA ±0.5%
F03P050S05 SENSOR CURRENT FLUX GATE 50A AC Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F03P
S25P050D15X SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Closed Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Current -40°C ~ 85°C 1µs ±0.5% Bidirectional 16mA ±0.15%
L01Z050S05 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -10°C ~ 80°C 10µs Bidirectional 15mA ±1%
F02P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F02P
F26P050S05A FLUX-GATE CS VREFOUT (50A; +5V Tamura Module, Single Pass Through Through Hole DC ~ 100kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 80°C (TA) 12.5mV/A 1µs ±0.96% Bidirectional 20mA ±1% F26P