Найдено: 27
Наименование Описание Производитель
Package / Case
Вид монтажа
Частота
Тип сенсора
Для измерения
Ток измеряемый
Number of Channels
Напряжение питания
Выход
Рабочая температура
Чувствительность
Response Time
Точность
Полярность
Ток потреблениея (макс)
Linearity
Серия
L18P050D15AHV CURRENT SENSOR (50A; 15V) Tamura Module Through Hole Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -30°C ~ 80°C (TA) 5µs Bidirectional 18mA ±1% L18PXXXD15
L08P050D15IPV CURRENT SENSOR (50A; 15V) Tamura Module, Single Pass Through Through Hole Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -40°C ~ 80°C (TA) 5µs Bidirectional 20mA ±1%
L08P050D15 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 10µs Bidirectional 12mA ±1%
F02P050S05 SENSOR CURRENT FLUX GATE 50A AC Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F02P
F23P050S05R FLUX-GATE CS VREFOUT (50A; +5V Tamura Module Through Hole DC ~ 100kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 12.5mV/A 500ns ±1.2% Bidirectional 55mA ±0.1% F23P
F03P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs Bidirectional 55mA ±0.1% F03P
L32P050S05BFS SENSOR CURRENT HALL 50A AC/DC Tamura Module, Single Pass Through Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 85°C 5µs Bidirectional 15mA ±0.5%
F03P050S05 SENSOR CURRENT FLUX GATE 50A AC Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F03P
S25P050D15X SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Closed Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Current -40°C ~ 85°C 1µs ±0.5% Bidirectional 16mA ±0.15%
L01Z050S05 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -10°C ~ 80°C 10µs Bidirectional 15mA ±1%
F02P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±0.9% Bidirectional 55mA ±1% F02P
F26P050S05A FLUX-GATE CS VREFOUT (50A; +5V Tamura Module, Single Pass Through Through Hole DC ~ 100kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 80°C (TA) 12.5mV/A 1µs ±0.96% Bidirectional 20mA ±1% F26P