Найдено: 27
Наименование Описание Производитель
Package / Case
Вид монтажа
Частота
Тип сенсора
Для измерения
Ток измеряемый
Number of Channels
Напряжение питания
Выход
Рабочая температура
Чувствительность
Response Time
Точность
Полярность
Ток потреблениея (макс)
Linearity
Серия
L18P050S12 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 12V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXS12
L18P050S05 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXS05
S23P50/100D15 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Closed Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Current -40°C ~ 85°C 0.5µs ±0.25% Bidirectional 25mA ±0.15% S23PXXXD15
L37S050S05J CURRENT SENSOR (50A; +5V) Tamura Module, Single Pass Through Chassis Mount DC ~ 50kHz Hall Effect, Open Loop DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 5µs Bidirectional 20mA ±1% L37S S05
L03S050D15 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 ±15V Ratiometric, Voltage -20°C ~ 80°C 5µs ±1% Bidirectional 12mA ±1%
L18P050S05R SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXS05
F01P050S05 SENSOR CURRENT FLUX GATE 50A AC Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±1.7% Bidirectional 55mA ±1% F01P
L32P050S05FS SENSOR CURRENT HALL 50A AC/DC Tamura Module, Single Pass Through Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 85°C 5µs Bidirectional 15mA ±0.5%
F01P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±1.7% Bidirectional 55mA ±1% F01P
L31S050S05FS SENSOR CURRENT HALL 50A AC/DC Tamura Module, Single Pass Through Chassis Mount DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 85°C 5µs Bidirectional 15mA ±0.5% L31SXXXS05S
L37S050S05M CURRENT SENSOR (50A; +5V) Tamura Module, Single Pass Through Chassis Mount DC ~ 50kHz Hall Effect, Open Loop DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 5µs Bidirectional 20mA ±1% L37S S05
L18P050D15-OP CURRENT SENSOR (50A; 15V) Tamura Module Through Hole Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -30°C ~ 80°C (TA) 5µs Bidirectional 18mA ±1% L18PXXXD15
F26P050S05 FLUX-GATE CS VREFOUT (50A; +5V Tamura Module, Single Pass Through Through Hole DC ~ 100kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 12.5mV/A 600ns ±0.96% Bidirectional 19mA ±1% F26P
L18P050D15 SENSOR CURRENT HALL 50A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 50A 1 ±15V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXD15
L37S050D15J CURRENT SENSOR (50A; 15V) Tamura Module, Single Pass Through Chassis Mount Hall Effect, Open Loop AC/DC 50A 1 ±12V ~ 15V Ratiometric, Voltage -40°C ~ 85°C (TA) 3µs Bidirectional 20mA ±1% L37S D15