L07P003D15S | SENSOR CURRENT HALL | Tamura | Module | Through Hole | Hall Effect, Open Loop | AC/DC | 3A | 2 | ±15V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 30mA | ±1% | L07P | ||
L18P003D15 | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | ±15V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 15mA | ±1% | ||
L16P003D15 | SENSOR CURRENT HALL 3A DC | Tamura | Module | Through Hole | DC ~ 35kHz | Hall Effect, Open Loop | DC | 3A | 1 | ±15V | Ratiometric, Voltage | -10°C ~ 80°C | 5µs | ±1% | Unidirectional | 12mA | ±1% | |
L07P003S05 | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | 5V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 30mA | ±1% | L07P | |
L18P003S05R | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | 5V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 15mA | ±1% | L18PXXXS05 | |
L18P003S05 | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | 5V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 15mA | ±1% | L18PXXXS05 | |
L18P003D15-OP | CURRENT SENSOR (3A; 15V) | Tamura | Module | Through Hole | Hall Effect, Open Loop | AC/DC | 3A | 1 | ±12V ~ 15V | Ratiometric, Voltage | -30°C ~ 80°C (TA) | 5µs | Bidirectional | 18mA | ±1% | L18PXXXD15 | ||
L07P003D15 | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | ±15V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 30mA | ±1% | L07P | |
L18P003D15AHV | CURRENT SENSOR (3A; 15V) | Tamura | Module | Through Hole | Hall Effect, Open Loop | AC/DC | 3A | 1 | ±12V ~ 15V | Ratiometric, Voltage | -30°C ~ 80°C (TA) | 5µs | Bidirectional | 18mA | ±1% | L18PXXXD15 | ||
L18P003S12 | SENSOR CURRENT HALL 3A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 3A | 1 | 12V | Ratiometric, Voltage | -30°C ~ 80°C | 5µs | Bidirectional | 15mA | ±1% | L18PXXXS12 | |
L10P003D15 | SENSOR CURRENT HALL 3A DC | Tamura | Module | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | DC | 3A | 1 | ±15V | Ratiometric, Voltage | -10°C ~ 80°C | 5µs | ±1% | Unidirectional | 12mA | ±1% |