Наименование | Описание | Производитель
|
Package / Case
|
Вид монтажа
|
Частота
|
Тип сенсора
|
Для измерения
|
Ток измеряемый
|
Number of Channels
|
Напряжение питания
|
Выход
|
Рабочая температура
|
Response Time
|
Точность
|
Polarization
|
Current - Supply (Max)
|
Серия
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CR4480-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400kHz | Transformer w/Conditioning | AC | 10A | 3 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 120mA | CR4400 |
CR5220S-10 | SENSOR CURRENT MAGNETIC 10A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Magnetic Modulator, Closed Loop | DC | 10A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 50mA | CR5200 |
CR5210S-10 | SENSOR CURRENT MAGNETIC 10A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Magnetic Modulator, Closed Loop | DC | 10A | 1 | 24V | Ratiometric, Voltage | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 35mA | CR5200 |
CR9580-10-M | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Hinged Ring, 0.40" Dia, Wire Leads | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | Self Powered | Ratiometric, 0 V ~ 5 V | -30°C ~ 60°C | 100ms (On), 250ms (Off) | ±0.5% | Bidirectional | CR9500 | ||
CR4150-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module, Dual Pass Through | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 10A | 2 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 75mA | CR4100 |
CR4120-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 10A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 40mA | CR4100 |
CR4220-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | CR4200 | |
CR4211-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | Self Powered | Ratiometric, 0 V ~ 10 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | CR4200 | |
CR4110S-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 10A | 1 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 25mA | CR4100 |
CR4260-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 2 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | CR4200 | |
CR9580-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Hinged Ring, 0.40" Dia, Wire Leads | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | Self Powered | Ratiometric, 0 V ~ 5 V | -30°C ~ 60°C | 100ms (On), 250ms (Off) | ±0.5% | Bidirectional | CR9500 | ||
CR4420S-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400kHz | Transformer w/Conditioning | AC | 10A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 45mA | CR4400 |
CR9550-10-M | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module, Single Pass Through | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | Self Powered | Ratiometric, 0 V ~ 5 V | -30°C ~ 60°C | 100ms (On), 250ms (Off) | ±0.5% | Bidirectional | CR9500 | ||
CR4170-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module, Triple Pass Through | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 10A | 3 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 60mA | CR4100 |
CR4210-10 | SENSOR CURRENT XFMR 10A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 10A | 1 | Self Powered | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | CR4200 |