- Напряжение питания
- Выход
- Рабочая температура
- Тип корпуса
- Чувствительность
- Response Time
- Точность
- Polarization
- Current - Supply (Max)
- Linearity
- Серия
Наименование | Описание | Производитель
|
Package / Case
|
Вид монтажа
|
Частота
|
Тип сенсора
|
Для измерения
|
Ток измеряемый
|
Number of Channels
|
Напряжение питания
|
Выход
|
Рабочая температура
|
Response Time
|
Точность
|
Polarization
|
Current - Supply (Max)
|
Linearity
|
Серия
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CR5220-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 100mA | CR5200 | |
CR5211S-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, ±10 V | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 35mA | CR5200 | |
CR5211-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, ±10 V | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 40mA | CR5200 | |
CR5210-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, Voltage | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 40mA | CR5200 | |
CR5220S-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 50mA | CR5200 | |
CR5210S-300 | SENSOR CURRENT HALL 300A DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC | Hall Effect, Closed Loop | DC | 300A | 1 | 24V | Ratiometric, Voltage | 0°C ~ 50°C | 250ms | ±1% | Unidirectional | 35mA | CR5200 | |
L37S300D15M | SENSOR | Tamura | Module | Chassis Mount | Hall Effect, Open Loop | DC | 300A | 1 | 15V | Ratiometric, Voltage | -40°C ~ 85°C | 3µs | Unidirectional | 20mA | ±1% | L37S D155 | ||
L37S300S05J | CURRENT SENSOR (300A; +5V) | Tamura | Module, Single Pass Through | Chassis Mount | DC ~ 50kHz | Hall Effect, Open Loop | DC | 300A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 5µs | Bidirectional | 20mA | ±1% | L37S S05 | |
L37S300S05M | CURRENT SENSOR (300A; +5V) | Tamura | Module, Single Pass Through | Chassis Mount | DC ~ 50kHz | Hall Effect, Open Loop | DC | 300A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 5µs | Bidirectional | 20mA | ±1% | L37S S05 |
- 10
- 15
- 50
- 100