- Voltage - Supply
- Output
- Operating Temperature
- Supplier Device Package
- Sensitivity
- Response Time
- Accuracy
- Polarization
- Current - Supply (Max)
- Linearity
- Series
Partnumber | Description | Manufacturer
|
Package / Case
|
Mounting Type
|
Frequency
|
Sensor Type
|
For Measuring
|
Current - Sensing
|
Number of Channels
|
Voltage - Supply
|
Output
|
Operating Temperature
|
Sensitivity
|
Response Time
|
Accuracy
|
Polarization
|
Current - Supply (Max)
|
Linearity
|
Series
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
L37S100D15M | SENSOR | Tamura | Module | Chassis Mount | Hall Effect, Open Loop | DC | 100A | 1 | 15V | Ratiometric, Voltage | -40°C ~ 85°C | 3µs | Unidirectional | 20mA | ±1% | L37S D155 | |||
F26P100S05A | FLUX-GATE CS VREFOUT (100A; +5 | Tamura | Module, Single Pass Through | Through Hole | DC ~ 100kHz | Flux Gate, Closed Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 80°C (TA) | 6.25mV/A | 1µs | ±0.96% | Bidirectional | 20mA | ±1% | F26P |
L01Z100S05 | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -10°C ~ 80°C | 10µs | Bidirectional | 15mA | ±1% | |||
L32P100S05FS | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module, Single Pass Through | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -40°C ~ 85°C | 5µs | Bidirectional | 15mA | ±0.5% | |||
S25P100D15X | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module, Single Pass Through | Through Hole | DC ~ 100kHz | Hall Effect, Closed Loop | AC/DC | 100A | 1 | ±12V ~ 15V | Ratiometric, Current | -40°C ~ 85°C | 1µs | ±0.5% | Bidirectional | 16mA | ±0.15% | ||
L03S100D15 | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | ±15V | Ratiometric, Voltage | -20°C ~ 80°C | 5µs | ±1% | Bidirectional | 12mA | ±1% | ||
L31S100S05FS | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module, Single Pass Through | Chassis Mount | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -40°C ~ 85°C | 5µs | Bidirectional | 15mA | ±0.5% | L31SXXXS05S | ||
F26P100S05 | FLUX-GATE CS VREFOUT (100A; +5 | Tamura | Module, Single Pass Through | Through Hole | DC ~ 100kHz | Flux Gate, Closed Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 6.25mV/A | 600ns | ±0.96% | Bidirectional | 19mA | ±1% | F26P |
L08P100D15 | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | ±15V | Ratiometric, Voltage | -10°C ~ 80°C | 10µs | Bidirectional | 12mA | ±1% | |||
F23P100S05R | FLUX-GATE CS VREFOUT (100A; +5 | Tamura | Module | Through Hole | DC ~ 100kHz | Flux Gate, Closed Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 6.25mV/A | 500ns | ±1.2% | Bidirectional | 110mA | ±0.1% | F23P |
S25P100D15Y | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Closed Loop | AC/DC | 100A | 1 | ±12V ~ 15V | Ratiometric, Current | -40°C ~ 85°C | 1µs | ±0.5% | Bidirectional | 16mA | ±0.15% | S25PXXXD15Y | |
L37S100S05M | CURRENT SENSOR (100A; +5V) | Tamura | Module, Single Pass Through | Chassis Mount | DC ~ 50kHz | Hall Effect, Open Loop | DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 5µs | Bidirectional | 20mA | ±1% | L37S S05 | ||
S23P50/100D15M1 | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Closed Loop | AC/DC | 100A | 1 | ±12V ~ 15V | Ratiometric, Current | -40°C ~ 85°C | 0.5µs | ±0.25% | Bidirectional | 50mA | ±0.15% | ||
L32P100S05BFS | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module, Single Pass Through | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -40°C ~ 85°C | 5µs | Bidirectional | 15mA | ±0.5% | |||
L08P100D15IPV | SENSOR | Tamura | Module | Through Hole | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | ±15V | Ratiometric, Voltage | -20°C ~ 80°C | 5µs | Bidirectional | 20mA | ±1% |
- 10
- 15
- 50
- 100