CAS 6-NP SENSOR CURRENT FLUX 6A AC/DC LEM USA Inc. Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 6A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C 104.2mV/A 0.3µs ±0.8% Bidirectional 20mA ±1% CAS
GO 10 SMS CURRENT TRANSDUCER INTEGRATED PR LEM USA Inc. 16-SOIC (0.295", 7.50mm Width) Surface Mount DC ~ 300kHz Hall Effect AC/DC 10A 1 4.5V ~ 5.5V Ratiometric, Voltage -40°C ~ 125°C (TA) 80mV/A 2µs ±1.3% Bidirectional 26mA ±0.3% GO-SMS
HAT 1200-S SENSOR CURRENT HALL 1200A AC/DC LEM USA Inc. Module Chassis Mount DC ~ 25kHz Hall Effect, Open Loop AC/DC 1200A 1 ±15V Ratiometric, Voltage -40°C ~ 105°C 5µs ±1% Bidirectional 15mA ±1% HAT
CKSR 50-NP KIT 3P SENSOR CURRENT FLUX AC/DC LEM USA Inc. Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 50A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 12.5mV/A 300ns ±0.8% 20mA ±0.1% CKSR
LES 6-NP SENSOR CURRENT HALL 6A UNIPOLAR LEM USA Inc. Module Through Hole 300kHz Hall Effect, Closed Loop AC/DC 6A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 105°C (TA) 104.2mV/A 400ns ±2.25% Bidirectional 23mA ±0.1% LES
HAW 07-P SENSOR CURRENT HALL 7.5A AC/DC LEM USA Inc. 8-DIP Module Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 7.5A 1 ±15V Ratiometric, Voltage -10°C ~ 75°C 3µs ±1% Bidirectional 18mA ±1% HAW
HOYS 560-S-0100 560A OPEN LOOP BAR BAR MOUNT LEM USA Inc. Module, Single Pass Through Chassis Mount DC ~ 180kHz Hall Effect, Open Loop AC/DC 560A 1 4.5V ~ 5.5V Ratiometric, Voltage -40°C ~ 105°C (TA) 1.429mV/A 3µs ±1% Bidirectional 25mA ±0.75% HOYS-S
HLSR 10-P/SP33 SENSOR CURRENT HALL 10A AC/DC LEM USA Inc. Module Through Hole 400kHz Hall Effect, Open Loop AC/DC 10A 1 3.3V Ratiometric, Voltage -40°C ~ 105°C 46mV/A 2.5µs ±1% Bidirectional 25mA ±0.5% HLSR-P/SP33
HLSR 10-P SENSOR CURRENT HALL 10A AC/DC LEM USA Inc. Module Through Hole 400kHz Hall Effect, Open Loop AC/DC 10A 1 5V Ratiometric, Voltage -40°C ~ 105°C 80mV/A 2.5µs ±1% Bidirectional 25mA ±0.5% HLSR-P
HO 120-NP SENSOR CURRENT HALL 120A AC/DC LEM USA Inc. Module Through Hole DC ~ 350kHz Hall Effect, Open Loop AC/DC 120A 1 5V Ratiometric, Voltage -40°C ~ 105°C 2.5µs ±1.25% Bidirectional 25mA ±0.5% HO-NP
HLSR 20-P/SP33 SENSOR CURRENT HALL 20A AC/DC LEM USA Inc. Module Through Hole 400kHz Hall Effect, Open Loop AC/DC 20A 1 3.3V Ratiometric, Voltage -40°C ~ 105°C 23mV/A 2.5µs ±1% Bidirectional 25mA ±0.5% HLSR-P/SP33
HY 50-P SENSOR CURRENT HALL 50A AC/DC LEM USA Inc. Module Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 3µs ±1% Bidirectional 10mA ±1% HY
HAS 100-S SENSOR CURRENT HALL 100A AC/DC LEM USA Inc. Module Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 100A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 3µs ±1% Bidirectional 15mA ±1% HAS
HOYS 100-S-0100 100 A OPEN LOOP BUS BAR MOUNT LEM USA Inc. Module, Single Pass Through Chassis Mount DC ~ 180kHz Hall Effect, Open Loop AC/DC 100A 1 4.5V ~ 5.5V Ratiometric, Voltage -40°C ~ 105°C (TA) 8mV/A 3µs ±1.25% Bidirectional 25mA ±0.75% HOYS-S
HLSR 20-SM/SP33 SENSOR CURRENT HALL 20A AC/DC LEM USA Inc. Module Surface Mount 400kHz Hall Effect, Open Loop AC/DC 20A 1 3.3V Ratiometric, Voltage -40°C ~ 105°C 23mV/A 2.5µs ±1% Bidirectional 25mA ±0.5% HLSR-SM/SP33