| Partnumber | Description | Manufacturer
|
Package / Case
|
Mounting Type
|
Frequency
|
Sensor Type
|
For Measuring
|
Current - Sensing
|
Number of Channels
|
Voltage - Supply
|
Output
|
Operating Temperature
|
Supplier Device Package
|
Sensitivity
|
Response Time
|
Accuracy
|
Polarization
|
Current - Supply (Max)
|
Linearity
|
Series
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CR4480-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400kHz | Transformer w/Conditioning | AC | 5A | 3 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 120mA | CR4400 | |||
| CR4110S-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 1 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 25mA | CR4100 | |||
| CR4110-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 1 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 25mA | CR4100 | |||
| CR4120S-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 40mA | CR4100 | |||
| CR4420-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400kHz | Transformer w/Conditioning | AC | 5A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 45mA | CR4400 | |||
| CR4150-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module, Dual Pass Through | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 2 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 75mA | CR4100 | |||
| CR4450-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400kHz | Transformer w/Conditioning | AC | 5A | 2 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 75mA | CR4400 | |||
| CR4210S-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 50Hz ~ 400Hz | Transformer w/Conditioning | AC | 5A | 1 | Self Powered | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | CR4200 | ||||
| CR4120-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 1 | 24V | Ratiometric, 4mA ~ 20mA | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 40mA | CR4100 | |||
| CR4170-5 | SENSOR CURRENT XFMR 5A AC | CR Magnetics Inc. | Module, Triple Pass Through | DIN Rail, Panel | 20Hz ~ 5kHz | Transformer w/Conditioning | AC | 5A | 3 | 24V | Ratiometric, 0 V ~ 5 V | 0°C ~ 60°C | 250ms | ±0.5% | Bidirectional | 60mA | CR4100 | |||
| CS05120B | CURRENT SENSOR,OPEN LOOP,5A,+/-1 | CUI Devices | Module | Through Hole | DC ~ 40kHz | Open Loop | AC | 5A | 1 | ±11.4V ~ 12.6V | Ratiometric, Voltage | -10°C ~ 75°C | 3µs | ±2.4% | Bidirectional | 25mA | ±0.5% | CSXX120B | ||
| SCD05PSR | SENSOR CURRENT HALL 5A AC | CUI Devices | Module | 50Hz ~ 60Hz | Hall Effect, Open Loop | AC | 5A | 1 | 12V | Ratiometric, Voltage | -10°C ~ 75°C | 3µs | Bidirectional | 25mA | ±0.5% | SCD | ||||
| CS0512U | CURRENT SENSOR, OPEN LOOP, 5 A, | CUI Devices | Module | Through Hole | DC ~ 40kHz | Open Loop | AC | 5A | 1 | 11.4V ~ 12.6V | Ratiometric, Voltage | -10°C ~ 75°C | 3µs | ±1.9% | Unidirectional | 25mA | ±0.5% | CSXX12U | ||
| AT 5 B10 | SENSOR CURRENT XFMR 5A AC | LEM USA Inc. | Module | Chassis Mount | 50/60Hz | Transformer w/Conditioning | AC | 5A | 1 | Self Powered | Ratiometric, 0 V ~ 10 V | -20°C ~ 60°C | 300ms | ±1.5% | Bidirectional | ±0.5% | AT | |||
| SI8501-C-IMR | SENSOR CURRENT XFMR 5A AC | Skyworks Solutions Inc. | 12-VFQFN | Surface Mount | 50kHz ~ 1MHz | Transformer w/Conditioning | AC | 5A | 1 | 2.7V ~ 5.5V | Ratiometric, Voltage | -40°C ~ 125°C | 12-QFN (4x4) | 392mV/A | ±5% | Unidirectional | 7mA |