AIMH021-100A-420B | CURRENT SENSOR 100A 4-20MA | Aim Dynamics | Module, Single Pass Through | Panel Mount | DC ~ 10kHz | Hall Effect | AC/DC | 100A | 1 | ±15V | Ratiometric, 4mA ~ 20mA | 10°C ~ 85°C | ±1% | Bidirectional | 25mA | AIMH021 | ||||
ACS752SCA-100 | SENSOR CURRENT HALL 100A AC/DC | Allegro MicroSystems | 5-CA Formed Leads, PFF | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -20°C ~ 85°C | 5-CA Module | 20mV/A | 8µs | ±1% | Bidirectional | 10mA | ±4.4% | |
ACS754SCB-100-PFF | SENSOR CURRENT HALL 100A AC/DC | Allegro MicroSystems | 5-CB Formed Leads, PFF | Through Hole | DC ~ 35kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -20°C ~ 85°C | 5-CB Module | 20mV/A | 11µs | ±0.9% | Bidirectional | 10mA | ±0.8% | |
CR5410-100 | SENSOR CURRENT HALL 100A AC/DC | CR Magnetics Inc. | Module | DIN Rail, Panel | DC ~ 4kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 24V | Ratiometric, Voltage | 0°C ~ 50°C | ±1% | Bidirectional | 40mA | CR5400 | ||||
HAL 100-S | SENSOR CURRENT HALL 100A AC/DC | LEM USA Inc. | Module | Panel Mount | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | ±15V | Ratiometric, Voltage | -25°C ~ 85°C | 3µs | ±1% | Bidirectional | 25mA | ±0.5% | HAL | ||
HAIS 100-P | SENSOR CURRENT HALL 100A AC/DC | LEM USA Inc. | Module | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -40°C ~ 85°C | 5µs | ±1% | Bidirectional | 19mA | ±0.5% | HAIS | ||
DHR 100 C5 | SENSOR CURRENT HALL 100A AC/DC | LEM USA Inc. | Module | Panel Mount | DC ~ 6kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 20V ~ 50V | Ratiometric, 0 V ~ 5 V | -40°C ~ 70°C | 150ms | ±1% | Bidirectional | 30mA | ±1% | DHR | ||
DHR 100 C10 | SENSOR CURRENT HALL 100A AC/DC | LEM USA Inc. | Module | Panel Mount | DC ~ 6kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 20V ~ 50V | Ratiometric, 0 V ~ 10 V | -40°C ~ 70°C | 150ms | ±1% | Bidirectional | 30mA | ±1% | DHR | ||
HC2F100-SN | SENSOR CURRENT HALL 100A AC/DC | LEM USA Inc. | Module | Through Hole | 20kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 125°C | 20mV/A | 15µs | Bidirectional | 20mA | ±0.2% | HC2F | ||
L31S100S05FS | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module, Single Pass Through | Chassis Mount | DC ~ 100kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | 5V | Ratiometric, Voltage | -40°C ~ 85°C | 5µs | Bidirectional | 15mA | ±0.5% | L31SXXXS05S | |||
L03S100D15 | SENSOR CURRENT HALL 100A AC/DC | Tamura | Module | Through Hole | DC ~ 50kHz | Hall Effect, Open Loop | AC/DC | 100A | 1 | ±15V | Ratiometric, Voltage | -20°C ~ 80°C | 5µs | ±1% | Bidirectional | 12mA | ±1% | |||
F26P100S05 | FLUX-GATE CS VREFOUT (100A; +5 | Tamura | Module, Single Pass Through | Through Hole | DC ~ 100kHz | Flux Gate, Closed Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 6.25mV/A | 600ns | ±0.96% | Bidirectional | 19mA | ±1% | F26P | |
T60404N4647X261 | CURRENT SENSOR 100A, PRI OPEN, 5 | VACUUMSCHMELZE | 8-DIP Module | Through Hole | DC ~ 100kHz | Closed Loop | AC/DC | 100A | 1 | 4.75V ~ 5.25V | Ratiometric, Voltage | -40°C ~ 85°C (TA) | 1µs | ±0.7% | Unidirectional | 15mA | ±0.1% | |||
T60404N4646X101 | CURRENT SENSOR, 100A, PRI OPEN, | VACUUMSCHMELZE | Module, Single Pass Through | Through Hole | DC ~ 200kHz | Closed Loop | AC/DC | 100A | 1 | ±11.4V ~ 15.75V | Ratiometric, Current | -40°C ~ 85°C (TA) | 1µs | ±0.5% | Unidirectional | 18mA | ±0.1% | |||
T60404N4646X100 | CURRENT SENSOR, 100A, PRI OPEN, | VACUUMSCHMELZE | Module, Single Pass Through | Through Hole | DC ~ 200kHz | Closed Loop | AC/DC | 100A | 1 | ±11.4V ~ 15.75V | Ratiometric, Current | -40°C ~ 85°C (TA) | 1µs | ±0.5% | Unidirectional | 18mA | ±0.1% |