Found: 280
Partnumber Description Manufacturer
Package / Case
Mounting Type
Frequency
Sensor Type
For Measuring
Current - Sensing
Number of Channels
Voltage - Supply
Output
Operating Temperature
Sensitivity
Response Time
Accuracy
Polarization
Current - Supply (Max)
Linearity
Series
S21S180D15JN SENSOR CURRENT HALL 180A DC Tamura Module Panel Mount DC ~ 200kHz Hall Effect, Closed Loop DC 180A 1 ±12V Ratiometric, Current -30°C ~ 80°C 1µs ±1% Bidirectional 16mA ±0.3%
L10P030D15 SENSOR CURRENT HALL 30A DC Tamura Module Through Hole DC ~ 50kHz Hall Effect, Open Loop DC 30A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 5µs ±1% Unidirectional 12mA ±1%
L18P025S05 SENSOR CURRENT HALL 25A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 25A 1 5V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXS05
L08P300D15IPV SENSOR Tamura Module, Single Pass Through Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 300A 1 15V Ratiometric, Voltage -20°C ~ 80°C 5µs Bidirectional 20mA ±1%
L12P025D15 SENSOR CURRENT HALL 25A AC/DC Tamura Module Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 25A 1 ±15V Ratiometric, Voltage -30°C ~ 80°C 3µs ±1% Bidirectional 15mA ±1%
L01Z500S05 SENSOR CURRENT HALL 500A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 500A 1 5V Ratiometric, Voltage -10°C ~ 80°C 10µs Bidirectional 15mA ±1%
L10P005D15 SENSOR CURRENT HALL 5A DC Tamura Module Through Hole DC ~ 50kHz Hall Effect, Open Loop DC 5A 1 ±15V Ratiometric, Voltage -10°C ~ 80°C 5µs ±1% Unidirectional 12mA ±1%
L32P050S05FS SENSOR CURRENT HALL 50A AC/DC Tamura Module, Single Pass Through Through Hole DC ~ 50kHz Hall Effect, Open Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 85°C 5µs Bidirectional 15mA ±0.5%
L18P030S05 SENSOR CURRENT HALL 30A AC/DC Tamura Module Through Hole DC ~ 100kHz Hall Effect, Open Loop AC/DC 30A 1 5V Ratiometric, Voltage -30°C ~ 80°C 5µs Bidirectional 15mA ±1% L18PXXXS05
F01P050S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 50A 1 5V Ratiometric, Voltage -40°C ~ 105°C 12.5mV/A 0.3µs ±1.7% Bidirectional 55mA ±1% F01P
F01P015S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 15A 1 5V Ratiometric, Voltage -40°C ~ 105°C 41.67mV/A 0.3µs ±1.9% Bidirectional 30mA ±1% F01P
L37S600S05J CURRENT SENSOR (600A; +5V) Tamura Module, Single Pass Through Chassis Mount DC ~ 50kHz Hall Effect, Open Loop DC 600A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 85°C (TA) 5µs Bidirectional 20mA ±1% L37S S05
L18P010D15AHV CURRENT SENSOR (10A; 15V) Tamura Module Through Hole Hall Effect, Open Loop AC/DC 10A 1 ±12V ~ 15V Ratiometric, Voltage -30°C ~ 80°C (TA) 5µs Bidirectional 18mA ±1% L18PXXXD15
F03P025S05D SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC 25A 1 4.75V ~ 5.25V Ratiometric, Voltage -40°C ~ 105°C 25mV/A 0.3µs Bidirectional 35mA ±0.1% F03P
F01P006S05L SENSOR Tamura Module Through Hole 300kHz Flux Gate, Closed Loop AC/DC 6A 1 5V Ratiometric, Voltage -40°C ~ 105°C 104.2mV/A 0.3µs ±2.5% Bidirectional 25mA ±1% F01P