Найдено: 20
Наименование Описание Производитель
Package / Case
Вид монтажа
Частота
Тип сенсора
Для измерения
Ток измеряемый
Number of Channels
Напряжение питания
Выход
Рабочая температура
Response Time
Точность
Полярность
Ток потреблениея (макс)
Linearity
Серия
DS400ID CURRENT TRANSDUCER 400A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 400A 1 ±14.25V ~ 15.75V -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.00015% DS
DL2000UB-10V CURRENT TRANSDUCER 2000A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 2000A 1 ±14.25V ~ 15.75V Ratiometric, Voltage -40°C ~ 65°C (TA) 1µs Bidirectional 190mA ±0.002% DL
SRCMH070IB+ TYPE B PROGRAMMABLE RESIDUAL CUR Danisense A/S Module, Single Pass Through Chassis Mount 100kHz AC Single Phase/Three Phase AC/DC 2A 1 24V 4mA ~ 20mA, Relay -20°C ~ 55°C Bidirectional
DL2000ID CURRENT TRANSDUCER 2000A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 2000A 1 ±14.25V ~ 15.75V Ratiometric, Current -40°C ~ 65°C (TA) 1µs Bidirectional 185mA ±0.0001% DL
DS600UB-10V CURRENT TRANSDUCER 600A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 600A 1 ±14.25V ~ 15.75V Ratiometric, Voltage -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.004% DS
DS200ID CURRENT TRANSDUCER 200A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 1MHz Flux Gate, Closed Loop AC/DC 200A 1 ±14.25V ~ 15.75V -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.0002% DS
DP50IP 50A PROGRAMMABLE CURRENT TRANSDU Danisense A/S Module Through Hole DC ~ 1MHz Flux Gate, Closed Loop AC/DC 12.5A, 25A, 50A (Selectable) 1 ±14.25V ~ ±15.75V Ratiometric, Current 0°C ~ 55°C (TA) 1µs 0.011% Bidirectional 42mA 0.001% DP
DS50ID CURRENT TRANSDUCER 50A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 1MHz Flux Gate, Closed Loop AC/DC 50A 1 ±14.25V ~ 15.75V -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.0008% DS
DQ600ID CURRENT TRANSDUCER 600A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 500kHz Flux Gate, Closed Loop AC/DC 600A 1 ±14.25V ~ 15.75V -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.0001% DQ
DS50UB-10V CURRENT TRANSDUCER 50A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 500kHz Flux Gate, Closed Loop AC/DC 50A 1 ±14.25V ~ 15.75V Ratiometric, Voltage -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.0024% DS
DM1200UB-10V CURRENT TRANSDUCER 1200A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 1200A 1 ±14.25V ~ 15.75V Ratiometric, Voltage -40°C ~ 65°C (TA) 1µs Bidirectional 141mA ±0.0015% DM
DC200IF CURRENT TRANSDUCER 200A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 200A 1 ±14.25V ~ 15.75V -40°C ~ 70°C (TA) 1µs Bidirectional 32mA ±0.0006% DC
DS1000UB-10V CURRENT TRANSDUCER 1000A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 300kHz Flux Gate, Closed Loop AC/DC 1000A 1 ±14.25V ~ 15.75V Ratiometric, Voltage -40°C ~ 55°C (TA) 1µs Bidirectional 104mA ±0.0035% DS
DS600ID CURRENT TRANSDUCER 600A Danisense A/S Module, Single Pass Through Chassis Mount DC ~ 500kHz Flux Gate, Closed Loop AC/DC 600A 1 ±14.25V ~ 15.75V -40°C ~ 85°C (TA) 1µs Bidirectional 104mA ±0.0001% DS
RCMH070IB+ TYPE B RESIDUAL CURRENT MONITOR Danisense A/S